The Rosemount XE10 CEMS provides reliable analysis of stationary source emissions. It is a standardized solution certified to the European emissions directives EN 14181 and EN 15267-3 (QAL1) and complies with the U.S. EPA 40 CFR Part 60 and Part 75 regulations. The Rosemount XE10 CEMS is also equipped with automated calibration to facilitate zero and span gas drift checks required for QAL3 quality assurance procedures, ensuring reliable performance and ongoing emissions reporting compliance. Contact us for more information on pricing and product details.
Specifications
Certifications/Approvals:
- EN 14181 standards compliant. Supports QAL3 drift test with integrated, automatic calibration and validation
- EN15267-1/EN15267-2/EN15267-3 (QAL1) certified
- CSA/Sira MCERTS certified
- TÜV Rheinland/Umweltbundesamt certified
- U.S. EPA 40 CFR Part 60 and 40 CFR Part 75 compliant
Detected Gas:
- CO, NOx or NO, SO2, CO2, O2
Ambient Temperature:
- Operation: 41 to 104 °F (5 to 40 °C)
- Storage: -4 to 158 °F (-20 to 70 °C)
Analog Output:
- 1 or 5, individually and optically isolated
- 4 (0)-20 mA (RB ≤ 500 Ω)
- NAMUR NE 43 and NE 44 compliance
Power Supply:
- 400 Vac 3-phase, 50 Hz
Dimensions:
- Width: 31.5 in. (800 mm)
- Height: 78.74 in. (2000 mm)
- Depth: 31.5 in. (800 mm)
Weight:
- Approximately 1058 lbs. (480 kg)